Kabel Fire Resistant Instrument Armoured 300/500 V
Untuk rangkaian tenaga listrik
Kabel Fire Resistant digunakan khusus untuk bangunan yang telah memenuhi persyaratan keselamatan yang tinggi seperti: emergency power supply station, pembangkit listrik, pabrik industri, pertambangan, stasiun kereta api, lokasi pembuatan kapal dan lepas pantai, lokasi pemrosesan data, sistem alarm, sistem ventilasi, eskalator, lift, sistem pencahayaan darurat, dll.
Kabel ini memiliki fitur tidak mengeluarkan gas beracun atau korosif jika terjadi kebakaran karena menghasilkan asap rendah dan bebas halogen serta mencegah penyebaran api. Untuk memastikan kinerja kabel tahan api, dilakukan pengujian sesuai dengan IEC 60331 (Sebelumnya IEC 331), BS 6387, SS 299 atau standar yang setara.
|
Rate Voltage
|
:
|
300/500 V
|
|
Symbol
|
:
|
Instrumentation Individual and Overall Screened Fire Resistant with Single Wire Armoured
( CU-MGT-XLPE-IS-OS-SWA-LSZH-1 )
(Copper Conductor, Mica Glass Tape Fire Barrier, XLPE Insulated, Overall Screen, Galvenized Steel Wire Armoured, LSZH Sheathed)
|
| Applicable Standard |
: |
Other Specification are available on request |
|
|
Size Ranged
|
:
|
- 1P - 50P x 1 mm2
- 1P - 50P x 1,5 mm2
- 1P - 50P x 2,5 mm2
- 1T - 50T x 1 mm2
- 1T - 50T x 1,5 mm2
- 1T - 50T x 2,5 mm2
|
| Specification |
: |
- IEC 60228
- BS EN 50288-7
- S 6387 Cat.CWZ
- IEC 60331
- IEC 60332-3 Cat.A, B, C
|
| Construction |
: |
Conductor |
: |
Plain annealed copper wire
As per IEC 60228 Class 2 |
| |
|
Fire Barrier |
: |
Mica glass Tape |
| |
|
Insulation |
: |
Extruded Cross-Linked Polyethylene (XLPE) |
| |
|
Individual Screen |
: |
Helically Overlapped Polyester Tape
Tinned Annealed Copper wire 0.5mm2 (20/0.18mm) Helically overlapped Single coated Aluminium Tape contacted with drain wire
Helically Overlapped Polyester Tape |
| |
|
Wrapping |
: |
Polyester binder tape |
| |
|
Overall Screen |
: |
Helically Overlapped Polyester Tape
Tinned Annealed Copper wire 0.5mm2 (20/0.18mm) Helically overlapped Single coated Aluminium Tape contacted with drain wire
Helically Overlapped Polyester Tape |
| |
|
Inner Sheath |
: |
Extruded Low Smoke Zero Halogen |
| |
|
Armour |
: |
Galvanized Steel Wire Aluminium Wire (Single Core) |
| |
|
Outer Sheath |
: |
Extruded Low Smoke Zero Halogen |
| |
|
Cable Marking |
: |
1. Manufacturer name ( JEMBO CABLE )
2. Type of cable : - Single Pair : IPCV - OS - SWA FR
- Multi Pair : IPCV - IS SWA FR
3. Rated Voltage ( 300/500 V )
4. Manufacturing Year |
|
Identification of Core
|
:
|
Single Pair
Multi Pair
Single Triad
Multi Triad
|
:
:
:
:
|
Black & White
Black & White with numbering
Black, White & Red
Black, White & Red with numbering
|
| Application |
: |
Fire Resistant Cables are requested for buildings especially high safety requirements, such as : |
| |
|
- Lifts and escalators
- High-rise buildings
- Hospitals
- Hotels
|
- Mass transit passanger systems
- Industrial Sites
- and other applications to aid in crisis or emergency situations.
|