Kabel Fire Resistant with Single Wire Armoured 300/500 V
For electric power circuit
Kabel Fire Resistant digunakan khusus untuk bangunan yang telah memenuhi persyaratan keselamatan yang tinggi seperti: emergency power supply station, pembangkit listrik, pabrik industri, pertambangan, stasiun kereta api, lokasi pembuatan kapal dan lepas pantai, lokasi pemrosesan data, sistem alarm, sistem ventilasi, eskalator, lift, sistem pencahayaan darurat, dll.
Kabel ini memiliki fitur tidak mengeluarkan gas beracun atau korosif jika terjadi kebakaran karena menghasilkan asap rendah dan bebas halogen serta mencegah penyebaran api. Untuk memastikan kinerja kabel tahan api, dilakukan pengujian sesuai dengan IEC 60331 (Sebelumnya IEC 331), BS 6387, SS 299 atau standar yang setara.
Construction:
1. Conductor | : | Plain annealed copper wire As per IEC 60228 Class 2 |
2. Fire Barrier | : | Mica tape |
3. Insulation | : | Cross Linked Polyethylene ( XLPE ) |
4. Colour Code | : | Black, white with number on insulation |
5. Individual Screen | : | Aluminium single coated with annealed tinned copper drain wire |
6. Wrapping | : | Polyester binder tape |
7. Overall Screen | : | Aluminium single coated with annealed tinned copper drain wire |
8. Inner Sheath | : | Flame retardant low smoke zero halogen thermoplastic compound ( FR - LS - OH ) |
9. Armour | : | Galvanized steel wire |
10. Outer Sheath | : | Flame retardant low smoke zero halogen thermoplastic compound ( FR - LS - OH ) |
11. Cable Marking | : | 1. Manufacturer name ( JEMBO CABLE ) 2. Type of cable : - Single Pair : IPCV - OS - SWA FR - Multi Pair : IPCV - IS SWA FR 3. Rated Voltage ( 300/500 V ) 4. Manufacturing Year |
Symbol | : | Instrumentation Individual and Overall Screened Fire Resistant with Single Wire Armoured ( CU-MGT-XLPE-IS-OS-SWA-LSZH-1 ) |
Applicable Standard | : | Other Specification are available on request |
Application | : | Fire Resistant Cables are requested for buildings especially hight safety requirements, such as: Emergency power supply station,Power stations and industrial plants,mines,under railway stations.Shipbuilding and offshore locations,data processing sites,alarm system,ventilation systems,escalators,lifts,emergency lighting systems, etc. The cable has feature not emit any toxic or corrosive gases in the event of fire due to produces low smoke and halogen free and prevents the spread of fire.To ensure the performance of fire resistant cables, a test is performed according to IEC 60331 ( Formerly IEC 331), BS 6387, SS 299 or equivalent standard. |